Hobart HO851G User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
– 13 –
Auto Start Hints
Do not use the Auto Start feature when the manual tray operation is engaged or if the ventilation
motor is controlled by an external source.
The oven will not Auto Start if the loading door is open.
To turn the Auto Start feature off, press the ON/OFF key under AUTO START section.
The Auto Start feature cannot be turned off once the purge cycles have started. A zero will be
displayed in the Timer number window when the purge cycles are in progress. The timer functions
cannot be adjusted during this time.
The oven has the ability to automatically select the auto start day of the week to match the operator’s
weekly schedule. (See Customizing Auto Start on page 14 for details.)
CUSTOMIZED OPERATION
The HO851G Rotary oven controls have the capability of being customized to t your speci c needs using
the Setup Mode.
Before entering the Setup Mode, read all the instructions to make sure you are completely clear on what
to do. If you need assistance, please call your authorized Hobart Bakery Systems service agency.
Entering/Exiting Setup Mode (without Auto Start)
1. Press and hold the DOWN arrow in the TIMER section while pressing the
.
2. The setup number will appear in the TIMER Hour and Minutes
window. The Tray Number window will ash. An alarm will
momentarily sound.
3. Release both keys. You are now in Setup Mode.
4. To exit Setup Mode, press and hold the same keys used in
step 1.
Entering/Exiting Setup Mode (with Auto Start)
1. Three keys need to be pressed at the same time to enter Setup
Mode:
The single RIGHT arrow in the TIMERS section
The FLIP TIME, HOLD TO SET key
The AUTO START, HOLD TO SET key
2. The setup number will appear in the TIMERS Hour and Minutes
window. The Tray Number window will ash. An alarm will
momentarily sound.
3. Release all keys. You are now in Setup Mode.
4. To exit Setup Mode, press and hold the same three keys used
in step 1.