DISH TABLES
Dish table end should be turned down and fitted over the lip
of the dishwasher tank (Fig. 4). Use an NSF approved sealer
between table and tank lip to prevent leaks. Fasten tables to
the tank lip; truss head screws (by others) are recommended.
PLUMBING CONNECTIONS
Fig. 4
WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY,
AND PLUMBING CODES.
The plumber who connects this machine is responsible for making certain that water lines are
THOROUGHLY FLUSHED OUT BEFORE connecting to any manual valve or solenoid valve. This
"flush-out" is necessary to remove all foreign matter, such as chips (resulting from cutting or threading
of pipes), pipe joint compound from the lines, or, if soldered fittings are used, bits of solder or cuttings
from the tubing. Debris, if not removed, may lodge in the valves and render them inoperative.
Manual valves or solenoid valves fouled by foreign matter, and any expenses resulting from this
fouling, are NOT the responsibility of the manufacturer.
Drain Connection
When the dishwasher is shipped from the factory, the drain pan is assembled so the drain (Fig. 5) exits
from the left side of the machine. If your plumbing arrangement requires the drain to exit from the right
side of the machine, rotate the drain pan and strainer, as follows:
1. Remove 2 screws and nuts at the front (Fig. 5) and 2 screws and nuts at the rear of the drain pan.
2. Turn drain pan and drain pan strainer 180° so the drain exits from the right side of the machine.
3. Secure drain pan by re-installing 2 screws and nuts at the front and 2 screws and nuts at the rear.
A 2" NPT fitting (external thread) is provided at the drain pan for proper connection to a suitable drain.
Fig. 5 Fig. 6
Water Supply Connection
A water hammer arrestor (meeting ASSE-1010 Standard) should be provided (by others) in the water
supply line ahead of its connection to the line strainer. Connect the water supply line to the line strainer
using
3
/4" pipe (Fig. 6).
The recommended water supply temperature is 140°F (60°C); minimum temperature is 120°F (49°C).
Flowing pressure of 20 – 25 psig is recommended (15 – 25 psig is required) at the dishwasher. If the
water pressure is higher than 25 psig, a pressure regulating valve with internal thermal expansion
bypass must be supplied (by others) in the water supply line. For convenience when cleaning, a water
tap should be installed near the machine with heavy duty hose and squeeze valve. Water must be
proper hardness. Recommended hardness range is 4 – 6 grains per gallon. Lower hardness promotes
corrosion, higher hardness may cause excessive formation of lime scale.
PL-40922-1
SIDE TABLE
SEAL TO
PREVENT LEAKAGE
PL-40923-1
FRONT SCREWS
DRAIN
PL-40924-1
LINE STRAINER
Page view 5